Basic Knowledge Of Daily Use Of The Micro Switch

Basic Knowledge Of Daily Use Of The Micro Switch

Basic Knowledge Of Daily Use Of The Micro Switch

스위치 구동 레버를 작동시키는 기계 및 장치의 부분을 나타냅니다.. 캠 및 스톱과 같은 기계 장비의 일부.

드라이브 로드: 스위치 부분입니다, 외부에서 내부 폭탄 구조로 힘을 전달하는, 그리고 가동 접점을 눌러 스위치 동작을 수행합니다. 버튼과 작동 레버의 일반 이름.

접촉 간격: The interval between the fixed and movable contact, the effective distance of the switch.

Switch Cover: the structure of the protection switch.

Movable piece: refers to the mechanical part of the switch contact. Sometimes called a movable spring.

단말기: The wiring works as a conductive part of a circuit for electrical input and output.

Terminology Description Of Switch Life Mechanical Life

Refers to the switch life when the contact is not energized, and the stroke (OT) is set to the specified value at the specified operating frequency to make it run.

전기적 수명: The switch life when the rated load is connected to the contact and the stroke (OT) is set to the specified value at the specified operating frequency.

Protection Level Against Electric Shock: Indicates The Level Of Protection Against Electric Shock, Which Has Four Levels.

Class 0: As an anti-shock measure, only essential insulation is used for protection.

클래스 I: As an anti-shock measure, a ground wire is added for protection in addition to essential insulation.

ClassⅡ: Double insulation or reinforced insulation protects against electric shock without grounding.

Class: : As an Anti-electric shock measure, as a safe ultra-low voltage (below 50VAC, or less than 7OVDC) circuit, there is no need to take anti-shock steps.

Precautions For The Use Of Microswitches

Choose the right switch.

Please select the appropriate switch and use it according to the use environment and load conditions.

Please select the appropriate switch in the selection guide according to the rated current, operating load, type of drive rod, and environmental conditions.

Using a switch that switches a larger current instead of remote current control will affect the contact’s reliability, so please avoid it as much as possible.

Please select a switch suitable for the switch current.

Use a sealed switch in an environment with many impurities and dust that liquids may be poured, such as water.

Use of switch

In actual use of the switch, some theoretically unforeseen accidents may occur. 그러므로, testing must be carried out within the scope of possible implementation. Unless otherwise specified, the rated performance values ​​recorded in the data refer to the matters ​​under the standard test state (temperature +15~+35℃, relative humidity 25~75%, air pressure 86~106kPa).

When testing with current equipment, please ensure that not only are the load conditions the same, but the use environment should also be the same as the actual use conditions. The reference data recorded is compiled into a graph from the actual values ​​sampled and measured from the production line and is not a guaranteed value.

The ratings and performance values ​​recorded in the data are obtained in individual tests. 아직, people cannot simultaneously guarantee the ratings and performance valuescombined conditions.

Operating Speed And Operating Frequency

The operating frequency and operating speed will affect the switch’s performance. Please note the following.

  1. If the operating speed is plodding, the switching of the contacts will be unstable, leading to poor communication and welding.
  2. The operation speed is breakneck and will become an impact action, causing early damage.
  3. If the operating frequency is high, switching contacts may not keep up.
  4. The operating frequency is shallow (less than one time/month), and an oxide film will be formed on the surface of the contact, resulting in a poor connection.

The allowable operating speed and acceptable operating frequency express the switch’s reliability. The life of the switch is a value at a specific operating speed. 그러므로, even within the allowable operating rate and frequency, its life may not be satisfied under certain conditions. Please perform confirmation experiments beforehand

About Usage Status

Please do not use it for a long time in a state of being pressed all the time. 그렇지 않으면, it will accelerate the deterioration of the parts and change their characteristics.

About The Operation Method Of The Switch

The operation method of the switch affects the performance of the button. Please pay attention to the following during operation.

  1. Please use a smooth-shaped switch operating body (cam, stopper, 등.). The drive rod of the button is quickly recovered, and when it receives an impact, it may damage the drive rod and make its life short.
  2. Please do not impose an unbalanced load on the drive rod during operation. 그렇지 않으면, local friction may cause damage to the drive rod and shorten its life.

Operate according to the operating direction of the drive lever. In the needle button type, press the button vertically.

  1. Please set the angle θ of the cam and stopper, such as the ball pendulum, within the range of 30 to 45°. If the angle is too large, it will cause abnormal lateral stress on the pendulum rod.
  2. When the drive rod is processed, the excessive external force will be applied to the switch’s internal mechanism, which will cause its characteristics to change and the switch to fail.
  3. When using the external swing lever as an operating body, we must determine the applied load according to the switch’s operating load.

Unionwell G5 시리즈 기본 마이크로 스위치 제품 목록 >>

후이저우 유니언웰 센싱 & 컨트롤전자㈜, 주식회사. 다양한 마이크로 스위치 생산 및 혁신에 전념하고 있습니다..

자세한 내용은, 저희 웹사이트를 방문해주세요: https://www.unionwellswitch.com.