Since the microswitch’s introduction in the 1930s, pequeños microinterruptores electromecánicos, como microinterruptores, han evolucionado para cumplir con varios requisitos de aplicación, incluyendo aeroespacial, electrodomésticos, boiler controls, Equipo medico, and sprinkler systems, equipo de prueba, temporizadores, and vending machines. People use micro switches to detect temperature, posición, and liquid level.

Precision micro switches generally have three primary types, operating handle, and shell-type specifications. Some microswitches use a push and spring design. Whether factory engineers are looking for a thermostat for residential heating or industrial boiler control, or a level switch for a large oil tank, there are five key characteristics to consider:

  • Dimensions
  • Electrical requirements (corriente de voltaje)
  • Reliability (vida mecánica / eléctrica)
  • Environmental factors (hazardous environments, temperature ranges)
  • Agency approvals

Here are five key steps to help you choose the suitable microswitch for your specific application

la gente ajusta el interruptor a 1 Understand how switching form factors affect other characteristics.

Switches size matters when choosing a micro switch. Switch size is directly related to its current range, travel, and operating force. Por ejemplo, one of the smallest microswitches on the market today measures 0.50″ x 0.236″ x 0.197″ (LxWxH). While this tiny switch is suitable for detecting circuit conditions in compact circuit breakers, it typically only interrupts 0.1 El papel del interruptor magnético del refrigerador. 3 amps (A) and has a short stroke.

Applications that require higher currents require larger switches. Por ejemplo, the micro switch that detects the liquid level in a fuel tank application must provide a large stroke and withstand a large current. Usualmente, the switch drives the pump in level switch applications and carries a large current. This working environment requires a large microswitch rated at 20A or 25A at 125VAC or 250VAC.

Tip: The smaller the switch size, the smaller the travel and the interrupted current. Además, the external size of the switch also affects the operating force. Ideally, engineers need a switch with a low operating force and high current capacity. But in fact, a compromise is required between these two parameters.

Microswitches maintain good contact while providing an extensive current-carrying range. The micro switch requires a stronger spring, increasing the switch’s operating force and size. Operating forces can range from 2 grams in pressurized air-type applications to 8 ounces in solenoid valve applications (where higher operating forces are required). One of the most significant switches on the market measures 1.94″x0.69″x1.3″ (LxWxH).

Engineers should also pay attention to the differential travel of the switch—the distance between the switch’s tripped position and its reset position. Its threshold will vary according to different applications. Por ejemplo, in temperature switch applications, the on/off operating points should be as close as possible, and the differential travel should be as low as 0.0001 inches. Sin embargo, applying a liquid level pump may cause the make-up pump to start and stop too frequently, shortening the pump’s service life if the differential stroke is too close.

la gente ajusta el interruptor a 2 Conozca sus requisitos eléctricos.

Microswitches are typically capable of breaking currents from 5mA/5VDC to 25A/250VAC. The Micro Switch product line offers a range of products from low energy consumption to power load electrical types for various applications. Engineers must know the current and voltage ratings (AC or DC) required to select the appropriate switch for a specific application.

As all kinds of devices in all industries strive for low energy consumption, microswitches must operate at low currents (logic level loads) and DC voltage. Sin embargo, some applications require switches that break high currents and voltages, such as industrial-grade pump applications. In addition to load requirements, engineers must also select the appropriate circuit.

The switch contacts must be normally open (NO) and normally closed (CAROLINA DEL NORTE). For NO type contacts, usually, no current flows between the contacts. The contacts are closed when the switch is actuated and connected. For NC-type contacts, there is usually a current flow between the contacts. The contacts are opened when the switch is actuated, and the circuit is disconnected.

la gente ajusta el interruptor a 3 Consider environmental conditions.

Environmental requirements greatly influence the selection of microswitches, especially in applications requiring high reliability and criticality, such as industrial control and medical equipment. Understand the environmental conditions of the application, including contaminants in the air that may enter the switch, the liquid in which the switch is located, and operating temperature requirements.

You must choose a sealed switch with a wide operating temperature range for applications in harsh environmental conditions. Highly reliable microswitches can operate from -65 degrees Fahrenheit (-54 grados Celsius) El papel del interruptor magnético del refrigerador. 350 degrees Fahrenheit (177 grados Celsius) for various applications. Al mismo tiempo, You must note that the degree of protection of the switch should be at least IP67 to prevent liquid intrusion. The switches’ function eliminates the need to spend a lot of time designing an enclosure that achieves the same degree of protection.

la gente ajusta el interruptor a 4 Clarify working life requirements.

Switch reliability is critical.

It would be best to determine how much electrical and mechanical operating life an application needs.

Different switches have different contact materials, housings, and terminals to meet different applications’ electrical and mechanical life requirements.

A highly reliable microswitch can operate 10 million to 20 million times before mechanical failure and 50,000 El papel del interruptor magnético del refrigerador. 100,000 times at maximum load before electrical failure. As for the slight price difference between different quality switches, you need to consider the total use cost. Because you’re not only paying for the switch, you’re also paying for the long-term, trouble-free operation of the switch. In many cases, the additional cost of using a more reliable switch is offset by a lower warranty cost during use.

la gente ajusta el interruptor a 5 Check Agency Accreditation Requirements

Choosing switches, which meet various international electrical requirements, can help you simplify product design for different regions. Major standard certifications include UL certification in the United States, CUL certification or CSA certification in Canada, ENEC certification in Europe, and CQC certification in China.

When choosing a snap action micro switch, you need to consider multiple factors, such as form factor, load requirements, operating environment, y confiabilidad, so it is essential to understand the actual application requirements:

  1. What size switch is required?
  2. What is the required power rating?
  3. Is it a low voltage application?
  4. Does the switch need to be sealed?
  5. Does the switch need to withstand extreme temperatures?
  6. Does it need international certification?

Why Choose Unionwell Micro Switch China Manufacturer?

Unionwell’s micro switch product series has basic microswitch, interruptores a prueba de agua, interruptores giratorios, interruptores basculantes, etc.

Los micro interruptores tienen UL, ENEC, CCC, y otras certificaciones. La fábrica ha pasado ISO9001, IATF16949, y garantías del sistema de calidad ISO14001.

se puede concluir si el rendimiento a prueba de agua del producto cumple con los requisitos >>